ANESTHESIA MACHINE – ETERNITY – AM834

ANESTHESIA MACHINE - ETERNITY - AM834

Specification :

• Display : 8.4″ TFT color touch screen

• Monitoring :

Volumes : MV, VTe, VTI

Pressures : Ppeak, Pmean, PEEP

Breath

Rate RATE spn

FiO2%

ETCO2 (Optional)

P-t, F-t waveforms, P-V and F-V Graph display Loops

Product Description

Specification :

• Display : 8.4″ TFT color touch screen

• Monitoring :

Volumes : MV, VTe, VTI

Pressures : Ppeak, Pmean, PEEP

Breath

Rate RATE spn

FiO2%

ETCO2 (Optional)

P-t, F-t waveforms, P-V and F-V Graph display Loops

Pneumatic Specification

• Gas Supply : O2, N2O, Air and Reserved O2

• Input Pressure : 0.3MPa~0.6MPa

• Yoke :1 x O2, 1 x N2O (Optional)

• Flowmeter : O2 :0~1L/min, 1~10L/min | N2O :0~1L/min, 1~10L/min | AIR :0~1L/min, 1~10L/min

• Pressure gauge : 3for pipeline gas, 2 for cylinder gas (Optional)

• O2 flush : 25~75L/min

• Operational Modes : Closed and semi-closed circuit system, semi open

• Driven mode : Pneumatically driven and electronically controlled

• AGSS (Passive) : Optional

• Gas Module (Optional) : CO2, AG

Breathing System

• APL Valve : 0.19~6KPa

• CO2 canister : 1800ml (Single Canister)

• Compensation for circuit leakage and compilance

• Bypass Function : (Optional)

Physical Specifications

• Dimension : L880 * W800 * H1580 mm

• Weight : 120kg

Electronic Specification

• Power Supply : AC100-240V±10%, 50/60Hz±1%

• Battery Backup : Minimum 120min

• Power Consumption : ≤70VA

• Top LED light

• RJ45 (optional)

Alarm

• High airway pressure / Low airway pressure

• High tidal volume / Low tidal volume

• High frequency / Low frequency

• High minute volume / Low minute volume

• High FiO2 / Low FiO2 (should option FiO2 function)

• Apnea

• Power Failure

• Low Battery

• Low Gas Supply

• Alarm Silence ≤120 seconds

Vaporizer

• Two vaporizer position (Selectatec with interlock)

• Optional two vaporizer positions

• Agent type : Sevoflurane, Halothane, Isoflurane and Enflurane

• Filling type : Pour-fill, Easy-fill, Quick-fill or Key-fill

• Compensation : Flow, pressure and temperature compensation

Ventilator Specification

• Patient Type : Pediatric and adult

• Ventilaton Mode : VCV, PCV, SIMV, STANDBY, Manual

• Tidal Volume : 15-1500ml

• Frequency : 0-100bpm, SIMV frequency : 4-20bpm

• I:E ratio : 10:1 – 1:10

• Inspiratory Pause : 0-60% of inspiratory time

• Inspiratory Time : 0.5 – 5S

• Pmax : 5-70cmH2O

• PEEP : OFF, 4-30cmH2O

• Pressure Trigger : 0-20cmH2O

• Flow Trigger : 0-20L/min